Evaluation of Efficiency of Persulfate Activated with Ultrasonic Waves in Phenanthrene Degradation from Soil Environments by Central Composite Design Method
Motahareh Harati , Roshanak Rezaei Kalantary
Professor, Department of Environmental Health Engineering, Iran University of Medical Sciences, Tehran, Iran
Abstract:   (102 Views)
Background and Purpose: PAHs and their derivatives have a complex and stable molecular structure with low biodegradability and have from the compounds in the crude oil. The object of this study was to evaluation of efficiency of persulfate activated with ultrasonic waves in Phenanthrene degradation from Soil environments by central composite design.
Methods: The soil samples were homogenized and filtered using a 2.0 mm sieve. Then, Phenanthrene solution (PHE) was added into soil sample. In order to carry out the chemical oxidation process, Probe Ultrasonic Wave Generator place out inside the reaction chamber Contains Persulfate/soil slurry environment. A central composite design (CCD) was used for designing and optimizing the operation parameters such as sodium Persulfate concentration, Ultrasound intensity and contact time. The synergy of processes in the system was also studied in optimal conditions.
Results: ANOVA results indicated that the effect of persulfate concentration, ultrasound intensity and contact time and binary interactions were significant. The Persulfate concentration, has the most significant effect on the phenanthrene degradation. The highest efficacy of the phenanthrene degradation (%58.05) was obtained in the conditions: initial concentration of persulfate =0.2 mol, ultrasonic waves with power = %70, and contact time = 120 min. By applying S2O8-2 in a separate approach after 120 min the efficiency was 9.2% while at these conditions, the efficiency of the ultrasonic process was only 3.4%. By contrast, the combined PS/US process could remove %58.05 of phenanthrene.
Conclusion: The results of this study indicated that, the application of the PS/US process is an effective method for purification of Phenanthrene contaminated soils.
Keywords: Phenanthrene, S2O82-, ultrasonic waves, soil
Full-Text [PDF 604 kb]   (78 Downloads)    
Type of Study: Research | Subject: Special
Received: 2018/10/2 | Accepted: 2018/10/2 | Published: 2018/10/2
Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Harati M, Rezaei Kalantary R. Evaluation of Efficiency of Persulfate Activated with Ultrasonic Waves in Phenanthrene Degradation from Soil Environments by Central Composite Design Method. jehe. 2018; 5 (4) :309-322
URL: http://jehe.abzums.ac.ir/article-1-541-en.html


Volume 5, Issue 4 (9-2018) Back to browse issues page
مجله مهندسی بهداشت محیط Journal of Environmental Health Enginering
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 3790