TY - JOUR T1 - The Monte Carlo Simulation of the Absorbed Equivalent Dose in Humans Modeling Due to Tehran Research Reactor and Radioactive Gases Released from It TT - استفاده از روش مونت کارلو برای شبیه سازی دز معادل جذب شده در یک مدل انسانی ناشی از عملکرد راکتورتحقیقاتی تهران و گازهای رادیو اکتیو متصاعد شده از آن JF - jehe JO - jehe VL - 3 IS - 1 UR - http://jehe.abzums.ac.ir/article-1-202-en.html Y1 - 2015 SP - 61 EP - 68 KW - Tehran Research Reactor (TRR) KW - Dose Equivalent KW - Code MCNPX KW - Radioactive Gases Under The Dome of KW - Phantom the Human. N2 - In this study, the annual and monthly equivalent dose of the operation of the Tehran Research Reactor in a human phantom in the pool and surrounding areas as well as the dome from the fission of radioactive gases (Kr, Xe, Cs, Ar, S, N, C, K, I) and suspended particulates emitted by the pool, were calculated by MCNPX code. The results show that the exposed doses by workers at the top and around the pool, when the limit was of the order of 408 hours and 1836 hours per year or speed of the air in such a way that the activity of gases given off by the pool, were reduced to 10% and 80% of the reported values explained by FSAR, respectively. M3 10.18869/acadpub.jehe.3.1.61 ER -