<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Environmental Health Engineering</title>
<title_fa>مجله مهندسی بهداشت محیط</title_fa>
<short_title>J Environ Health Eng</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jehe.abzums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2383-3211</journal_id_issn>
<journal_id_issn_online>2588-4239</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jehe</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی پارامترها و مشکلات بهره برداری سیستم هوادهی گسترده لجن فعال و ارائه راهکارهای مناسب جهت بهبود کارایی تصفیه خانه فاضلاب بیمارستان گلستان اهواز</title_fa>
	<title>Study of Operational and Maintenance Problems and Parameters of Extended Aeration Activated Sludge Process in Golestan Hospital Wastewater Treatment Plant, Ahvaz, and Their Solutions</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;فاضلاب بیمارستانی جزء زائدات خطرناک محسوب شده و به لحاظ کمیت و برخورداری از ترکیبات سمی و خطرناک و داشتن عوامل میکروبی بیماری زا، در صورت عدم تصفیه و دفع نامناسب، مخاطرات زیادی را بر محیط زیست و انسان ایجاد می&lt;/span&gt;&amp;shy;&lt;span dir=&quot;RTL&quot;&gt;نماید. هدف از این تحقیق بررسی پارامترهای بهره برداری و نگهداری فرایند بیولوژیکی واحد لجن فعال هوادهی گسترده تصفیه خانه فاضلاب بیمارستان گلستان اهواز می&lt;/span&gt;&amp;shy;&lt;span dir=&quot;RTL&quot;&gt;باشد. &amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;مواد و روش ها:&lt;/span&gt;&lt;/strong&gt;در این پژوهش نمونه برداری در 6 ماه (دی تا خرداد) سال 1393 انجام شد و پارامترهای &lt;span dir=&quot;LTR&quot;&gt;BOD5, COD, TSS&lt;/span&gt; در فاضلاب خام ورودی و پساب خروجی و میزان &lt;span dir=&quot;LTR&quot;&gt;VLR,Qr/Q,MLSS,F/M,SVI,HRT,&amp;theta;c&lt;/span&gt; درحوضچه هوادهی اندازه&amp;shy; گیری و در نهایت پارامترهای راهبری و بهره &amp;shy;&amp;shy;برداری با استفاده از معادلات مربوطه محاسبه گردیده است.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;نتایج نشان داد که میانگین پارامترهای بهره برداری و نگهداری برابر:&lt;/span&gt;&amp;nbsp;HRT = 6 hour ،&amp;nbsp;&amp;theta;c = 10.93، &amp;nbsp;F/M = 0.35 &amp;nbsp; MLSS=2819.36&amp;nbsp;،&amp;nbsp;&amp;nbsp;VLR = 1.1 Kg BOD/m&lt;sup&gt;3&lt;/sup&gt;.d ، SVI = 144.89 ml/g ، Qr/Q = 64.28 حوض هوادهی می باشد.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;نتیجه گیری:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;نتایج نشان داده است که سیستم تصفیه فاضلاب بیمارستان گلستان در ابتدای راه اندازی تصفیه&amp;shy; خانه که تعداد بخش&amp;shy;های بستری در بیمارستان کم بود، از نوع سیستم لجن&amp;shy;فعال با هوادهی گسترده بوده ولی با افزایش تعداد تخت&amp;shy;ها و گسترش بیمارستان و متعاقبأ افزایش مصرف آب و تولید فاضلاب بیشتر، منجر به افزایش بارهیدرولیکی و رقیق شدن بار آلی ورودی به تصفیه خانه شده است که در نتیجه آن، زمان ماند هیدرولیکی و سن لجن پایین آمده و سیستم تصفیه&amp;shy;خانه رفتار لجن فعال متعارف را به جای هوادهی گسترده ایفا می&amp;shy;کند و پارامترهای راهبری در محدوده این سیستم تصفیه می&amp;shy;باشند.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background:&lt;/strong&gt;Hospital wastewater is among hazardous wastewater due to its composition of pathogens and toxic chemicals. Discharge of untreated hospital wastewater to environment is hazardous for human and environment. Aims of this study were to identify Operational and Maintenance problems of Extended Aeration Activated sludge process in Golestan Hospital wastewater treatment plant (WTP), Ahwaz, Iran, and to find their solutions. &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &lt;strong&gt;Materials and Methods:&lt;/strong&gt;Sampling period was 6 months of 2015. BOD&lt;sub&gt;5&lt;/sub&gt;, COD, and TSS parameters analysed in the hospital WTP effluent. In addition, VLR, Qr/Q, MLSS, F/M, SVI, HRT, and &amp;theta;c parameters measured in aeration tank, then operational and maintenance parameters calculated. &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &lt;strong&gt;Results:&lt;/strong&gt;Results shown that average of operation &amp; maintenance parameters were: F/M = 0.35, HRT = 6 hour, Qr/Q = 64.28 %, VLR = 1.1 Kg BOD/m&lt;sup&gt;3&lt;/sup&gt;.d, MLSS = 2819.36 mg/l, SVI = 144.89 ml/g, &amp;theta;c = 10.93 days. &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &lt;strong&gt;Conclusion:&lt;/strong&gt;Results of operational and maintenance parameters shown that biological process behavior of the hospital WTP was Extended Aeration Activated Sludge in past years, but converted to conventional activated sludge process due to increase in hospital beds of clinical and out patients departments , which increased water consumption lead to increase wastewater flow rate. High flow rate lead to increase hydraulic load and diluting organic matter load, so hydraulic retention time and sludge age decreased.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;div style=&quot;margin-left: 42.55pt;&quot;&gt;
&lt;p&gt;&lt;/p&gt;
&lt;/div&gt;
</abstract>
	<keyword_fa>فاضلاب بیمارستانی, فرایند لجن فعال, بهره برداری تصفیه خانه  </keyword_fa>
	<keyword> Hospital Wastewater, Activated Sludge, Operation Treatment </keyword>
	<start_page>270</start_page>
	<end_page>279</end_page>
	<web_url>http://jehe.abzums.ac.ir/browse.php?a_code=A-10-25-26&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Afshin</first_name>
	<middle_name></middle_name>
	<last_name>Takdastan</last_name>
	<suffix></suffix>
	<first_name_fa>افشین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>تکدستان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001374</code>
	<orcid>10031947532846001374</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشیار مرکز تحقیقات فناوری های زیست محیطی دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز</affiliation_fa>
	 </author>


	<author>
	<first_name>Bahareh</first_name>
	<middle_name></middle_name>
	<last_name>Kordestani</last_name>
	<suffix></suffix>
	<first_name_fa>بهاره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کردستانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001375</code>
	<orcid>10031947532846001375</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی بهداشت محیط بیمارستان گلستان، دانشگاه علوم پزشکی جندی شاپور اهواز</affiliation_fa>
	 </author>


	<author>
	<first_name>Abdolkazem</first_name>
	<middle_name></middle_name>
	<last_name>Nisi</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالکاظم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نیسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001376</code>
	<orcid>10031947532846001376</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشیار مرکز تحقیقات فناوری های زیست محیطی دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز</affiliation_fa>
	 </author>


	<author>
	<first_name>Reza</first_name>
	<middle_name></middle_name>
	<last_name>Jalilzadeh Yangjeh</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جلیل زاده ینگجه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001377</code>
	<orcid>10031947532846001377</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>3 استادیار گروه مهندسی محیط زیست، واحد اهواز، دانشگاه آزاد اسلامی ، اهواز،</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
