@article{ author = {Hosaini, Mohammad and Moradi, Rohallah and Safari, Gholam Hossai}, title = {Efficiency Evaluation of Filtration with Fluidized Bed for Treatment of Secondary Effluents for Reuse}, abstract ={Background & Objectives: Recently, deficient in atmospheric drop and discharges of wastewater effluents leads to serious threat for water resource. For that reason, for prevention of water source pollution and also reuse of wastewater effluents, treatment of such effluents seems to be necessary. Methods: In this work, fluidized bed reactor with a filter was used for treatment of effluents from Shahrak Gharb wastewater treatment plant. Various parameters such as BOD5, COD, TS, TP, TN and turbidity were analyzed. The aluminum sulfate was used as coagulant for enhance removal efficiency. Results: The results of present work demonstrate that present system had higher treatment potential for secondary effluents. The amount of BOD5, COD and TP in system effluents was reached to below 1.75, 3.23, 0.5 mg/L, respectively. No removal efficiency was observed for TN. In addition, the amount of turbidity in system effluent was reached to below 1.04 NTU. The system represents lower removal efficiency for TS. In addition, higher removal efficiency is in the range of 5 to 7.5 m/h and increasing of surface loading upon to 10 m/h will decreases the removal efficiency. Conclusion: On general, the system represents higher removal potential for treatment of secondary effluent for reuse application.}, Keywords = {secondary effluents, reuse, fluidized reactor, filtration }, volume = {1}, Number = {1}, pages = {1-10}, publisher = {alborz university of medical sciences}, title_fa = {کاربرد فیلتراسیون با مدیای شناور در تصفیه پساب ثانویه به منظور استفاده مجدد}, abstract_fa ={زمینه و هدف: به دلیل کمبود ریزش‌های جوی و تخلیه پساب‌های تصفیه خانه، منابع تأمین آب شرب با تهدید جدی مواجه شده است. برای این منظور تصفیه پساب ثانویه جهت مصارف مجدد ضروری می‌باشد. روش‌بررسی: در این مطالعه از یک راکتور حاوی بستر سیال به همراه یک واحد فیلتراسیون جهت تصفیه پساب تصفیه خانه شهرک غرب استفاده شد. پارامترهای مختلفی از قبیل BOD5 ، COD، TS، فسفر کل، نیتروژن کل و کدورت مورد سنجش قرار گرفت. یافته‌ها: نتایج حاصل از این پژوهش نشان داد که فیلتراسیون با مدیای شناور قابلیت بسیار بالایی در تصفیه پساب ثانویه دارد. در این مطالعه مشخص گردید که فرآیند مورد نظر قادر است BOD5 و COD را به ترتیب به 75/1 و mg/L 23/3 برساند. همچنین کدورت خروجی از سیستم برابر NTU 04/1 و فسفر کل به کمتر از mg/L 5/0 رسید. از طرف دیگر هیچ گونه راندمان حذفی برای نیتروژن کل مشاهده نگردید و میزان جامدات کل پساب نیز در حد بسیار کم حذف گردید. همچنین بیشترین مقدار حذف پارامترهای مورد نظر در بارهای سطحی 5 تا 5/7 m/h مشاهده گردید. نتیجه‌گیری: نتایج حاصل از این مطالعه نشان داد که سیستم مورد استفاده قادر است پساب ثانویه را تاحدی تصفیه کند که بتوان از آن در مصارف ثانویه از قبیل کشاورزی و یا آبیاری استفاده کرد.}, keywords_fa = {کلمات کلیدی: پساب ثانویه, استفاده مجدد, مدیای شناور, فیلتراسیون}, doi = {10.18869/acadpub.jehe.1.1.1}, url = {http://jehe.abzums.ac.ir/article-1-23-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-23-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Norisepehr, Mohammad and Golbaz, Somayeh and Jarghi, Sah}, title = {Comparision of Chitosan Function as Adsorbent for Nitrate Removal Using Synthetic Aqueous Solution and Drinking Water}, abstract ={Background & Objectives: Nitrate and nitrite compounds pollution of groundwater resources in recent years which recently their mean concentration due to enhancement of different kind of municipal, industrial and agriculture waste water, were increased. The most common source of nitrates entering the water include chemical fertilizers and animal manure in agriculture, septic tank effluent, wastewater, wastewater treatment plants, animal and plant residue analysis on the ground of non-sanitary disposal of solid waste and the use of absorbing wells for sewage disposal. Materials and methods: This experimental study is applied to the nitrate removal using chitosan in laboratory scale at ambient temperature and the design of the system was Batch. Effects of parameters such as pH, contact time, initial concentration and adsorbent concentration of nitrate on nitrate removal from aqueous solution was studied. Results: Function of chitosan in synthetic aqueous solution and drinking water according to the slurry system results, the optimum condition was obtained at pH=4, 20 min contact time and increasing the initial concentration of nitrate enhance the adsorption capacity of chitosan. Also optimum dosage of adsorbent was obtained at 0.5 g/l. The data obtained from the experiments of adsorbent isotherm were analyzed using Langmuir and Freundlich isotherm models. The Langmuir equation was found to be the best fitness with the experimental data (R2>0.93). Conclusion: Although efficiency of Nitrate removal in synthetic aqueous solution was better than drinking water, adsorption process using chitosan as an option for the design and selection nitrate removal should be considered in order to achieve environmental standards.}, Keywords = {Chitosan, Nitrate, Adsorbtion, Isotherm, Drinking water}, volume = {1}, Number = {1}, pages = {11-19}, publisher = {alborz university of medical sciences}, title_fa = {مقایسه عملکرد کیتوزان بعنوان جاذب در حذف نیترات از محلول آبی سنتتیک و آب آشامیدنی شهری}, abstract_fa ={زمینه و هدف: ترکیبات نیترات و نیتریت از عوامل آلاینده منابع آب های زیرزمینی هستند که در سال‌های اخیر میزان متوسط آنها در آب های زیرزمینی به علت گسترش انواع فاضلاب های شهری، صنعتی و کشاورزی رو به افزایش است. متداولترین منبع ورود نیترات به منابع آب شامل کاربرد کود شیمیایی و کودهای حیوانی در کشاورزی، پساب سپتیک تانک، پساب تصفیه خانه های فاضلاب، تجزیه بقایای حیوانی و گیاهی در زمین، دفع غیر بهداشتی مواد زاید جامد و استفاده از چاه های جذبی برای دفع فاضلاب است. روش کار: این تحقیق یک مطالعه تجربی کاربردی می‌باشد که به منظور حذف نیترات با استفاده از کیتوزان در شرایط دمای محیط طراحی و در مقیاس آزمایشگاهی و به صورت سیستم بسته انجام شد. اثر پارامترهایی مانند pH، زمان تماس، غلظت جاذب و غلظت اولیه نیترات بر حذف نیترات از محلول آبی مورد مطالعه قرار گرفت. یافته‌ها: عملکرد کیتوزان در محلول آبی سنتتیک و آب آشامیدنی شهری بر طبق سیستم دوغاب pH بهینه 4، زمان تعادل 20 دقیقه و افزایش غلظت اولیه نیترات باعث بالا رفتن ظرفیت جذب شد. همچنین مقدار بهینه جاذب g/L 5/0 بدست آمد. نتایج حاصل از ایزوترم جذب با استفاده از مدل لانگمویر و فروندلیچ مورد آنالیز قرار گرفت. مدل لانگمویر بیشترین همخوانی را با داده‌های آزمایش داشت   (93/0< R2). نتیجه‌گیری: اگرچه راندمان حذف نیترات در محلول آبی سنتتیک بهتر از آب آشامیدنی می‌باشد اما روش فرایند جذب سطحی با استفاده از کیتوزان می‌تواند به عنوان گزینه‌ای مناسب به هنگام طراحی و انتخاب روش حذف نیترات جهت دستیابی به استانداردهای زیست محیطی مد نظر قرار گیرد.}, keywords_fa = {کیتوزان, نیترات, جذب, ایزوترم, آب آشامیدنی}, doi = {10.18869/acadpub.jehe.1.1.11}, url = {http://jehe.abzums.ac.ir/article-1-24-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-24-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Norozi, Roghaieh and Zafarzade, Ali and Yolizade, Taher}, title = {Survey on Microbial Quality of Drinking Water in City Maravehtapeh Villages and Comparison with National and WHO Standards}, abstract ={Background and Objectives: The objective of the study is survey on microbial quality of Maravehtapeh village in during September and October 1391, and its quality compared with national standards and WHO. Material and Methods: In this cross- sectional study, the water microbial quality in 90 villages have piped city-wide network based on two criteria were assessed total and fecal coliform. 3 samples from each village were sampled during three months. Samples were survey A nine-tube fermentation test s for coliform group. For chlorine residual of diethyl – p- phenylene diamine (DPD) colorimetric method was used. Results: In this paper, the results of date from 3 round of sampling and testing are presented. The results show that 83.64, 71.43 and 78.89% village with coverage and no coverage of Rural Waste Water Company and all maravehtapeh villages, respective, using safe water in terms of FC and 54.3, 36.37 and 43.34% village with coverage and no coverage of Rural Waste Water Company and all maravehtapeh villages, respective, using safe water in terms of TC. Conclusion: The results of this study express that the fecal contamination condition in under coverage village is good. But there is a bad condition in villages with no coverage of KRWWC. And the general microbial quality of drinking water in all Maravehtapeh villages of the World Health Organization and country Microbial Index is low.}, Keywords = {Drinking water, Microbial Quality, coliform}, volume = {1}, Number = {1}, pages = {20-29}, publisher = {alborz university of medical sciences}, title_fa = {بررسی کیفیت میکروبی آب آشامیدنی روستاهای شهرستان مراوه تپه و مقایسه آن با استانداردهای WHO ملی}, abstract_fa ={زمینه و هدف: هدف این مطالعه تعیین کیفیت میکروبی آب آشامیدنی روستاهای شهرستان مراوه تپه در ماه های شهریور تا آبان سال 1391 و مقایسه کیفیت ان با استانداردهای ملی و WHO می‌باشد. روش کار: در این مطالعه توصیفی-مقطعی ،کیفیت میکروبی آب 90 روستای دارای شبکه لوله کشی سطح شهرستان بر اساس 2 معیار کل کلیفرم وکلیفرم مدفوعی مورد سنجش قرار گرفت. تعداد 3 نمونه از هر روستا در طول سه ماه نمونه برداری گردید. نمونه‌ها به روش آزمایش تخمیر نه لوله ای برای گروه کلیفرمها، مورد بررسی قرار گرفتند. برای بررسی کلر باقی مانده از دی اتی-پی- فنیلن دی آمین (DPD) با روش رنگ سنجی استفاده شد. یافته‌ها: در این مطالعه نتایج حاصل از سه مرحله نمونه برداری وآزمایش ارائه شده است .نتایج نشان می‌دهد64/83، 43/71 و 89/78 درصد روستاهای تحت پوشش ، غیرتحت پوشش شرکـت آبفار و کل روستاهای شهرستان مراوه تپه از آب سالم از نظر کلیفرم مدفوعی و 3/54، 37/36 و 34/43 درصد از روستاهــای تحت پوشش، غیرتحت پوشش شرکت آبفار وکل روستاهای شهرستان مــــراوه تپه از آب سـالم از نظر کلیفرمی بهره مند بودند. میزان کــلر باقیمانده آزاد روستاهای تحت پوشش، غیرتحت پوشش شرکت آبفار وکـل روستاهای شهرستان مراوه تپه با میانگین 15/0، 99/0 11/0میلی‌گرم بر لیــتر می‌باشد. نتیجه‌گیری: نتایج مطالعه حاضر نشان می‌دهد که وضعیت روستاهای تحت پوشش از لحاظ آلودگی مدفوعی خوب است. ولی برای روستاهای غیرتحت پوشش شرایط نامناسبی حاکم است. و به طور کلی کیفیت میکروبی آب آشامیدنی کل روستاها از شاخص میکروبی سازمان جهانی بهداشت و استاندارد کشور پایین است.}, keywords_fa = {آب شرب, کیفیت میکروبی, کلیفرم}, doi = {10.18869/acadpub.jehe.1.1.20}, url = {http://jehe.abzums.ac.ir/article-1-25-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-25-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Naseri, Simin and Monazzam, Mohammad Reza and Beheshti, Maisam and Saiyedi, Shoj}, title = {Investigation of Vertical Microwave Publishing Caused by the Base Transceiver Station (BTS) Antennas in Hashtgerd City}, abstract ={Background and Objectives: New Hazards interface the environment and human life along with technology development. One of these pollutants is electromagnetic field and it’s known and unknown bad effects on the environment, this study determines the vertical publishing (height measurement) of microwave antennas in the city of Hashtgerd. Methods: The basic information including the geographical location of the BTS antennas in the city, brand, the operator type, installation and its height was received from CRA and radio communications, and then the measuring was done by using the standard method of IEEE STD 95. 1 by the SPECTRAN 4060, and by using crane elevator in 17-meters height near the BTS antennas (15 meters).analysis were done by Spss16 and by Kolmogorov Smirnov test, multiple regression method. Results: Results show that in the both operators of Irancell and Hamrah-e-aval, density will increase by increasing measurement height or decreasing the vertical distance of broadcaster antenna. Regarding to the mix model test, a meaningful statistical relationship can be seen between measurement height and the density average in both types of the operators. Conclusion: while measuring height increased or in other words got closer to the antennas, density average increased in both operators, so the highest number was reported in the minimum vertical distance compared to the Irancell operator antenna was 25 mw/m2 and the lowest number was related to Hamrah-e-aval operator in the maximum vertical distance which was 0.02mw/m2. Thus, people stationed in the tall buildings parallel with installation height of antennas or in less vertical distance of them, are more exposed to the waves.}, Keywords = {vertical measuring, microwave, Hashtgerd, BTS antennas}, volume = {1}, Number = {1}, pages = {30-36}, publisher = {alborz university of medical sciences}, title_fa = {سنجش چگالی توان امواج الکترومغناطیسی ناشی از آنتن‌های بی تی اس در شهر هشتگرد با رویکرد بررسی اثرات}, abstract_fa ={مقدمه: به همراه رشد فن آوری ،آلاینده‌های جدیدی میهمان ناخوانده محیط زیست انسانها شده اند.یکی از این آلاینده‌ها میدان های الکترومغناطیسی و آثارسوء شناخته شده و ناشناخته ناشی از آنهاست .این مطالعه وضعیت انتشار عمودی (سنجش در ارتفاع) امواج مایکروویو ناشی از آنتن‌های بی تی اس( Base Transceiver Station) در شهر هشتگرد را بررسی می‌کند. مواد و روش‌ها: در گام اول، اطلاعات پایه شامل محل استقرار جغرافیایی آنتن‌های بی تی اس در سطح شهر هشتگرد، برند (ایرانسل و همراه اول) ،نوع اپراتور،نوع نصب و ارتفاع نصب از سازمان‌های ذیربط دریافت گردید. سپس با استفاده از روش استانداردIEEE STD C 95.1 و توسط دستگاه SPECTRAN - 4060 و با استفاده از جرثقیل بالابر 17 متری که در مرز میدان نزدیک (15 متری) و میدان دور آنتن‌های بی تی اس استقرار یافت سنجشها انجام شد . داده‌های حاصل توسط نرم افزار SPSS 16 و با استفاده از آزمون کولموگروف اسمیرنوف و مدل رگرسیون چند گانه مورد تجزیه و تحلیل قرار گرفت. نتایج و بحث: نتایج این مطالعه نشان می‌دهد در هر دو اپراتور ایرانسل و همراه اول با افزایش ارتفاع سنجش از سطح زمین و به عبارت دیگر با کاهش فاصله عمودی نسبت به آنتن فرستنده ،میانگین چگالی توان افزایش می‌یابد به طوری که میانگین چگالی توان اپراتور ایرانسل افزایش بیشری را در فواصل بالای 10متر نشان داده ولی کاهش میانگین چگالی توان در فواصل کمتر ناشی از مداخلات ساختمان‌ها در نوع ایرانسل می‌باشد. به طوری که بیشترین عدد در کمترین فاصله عمودی نسبت به آنتن اپراتور ایرانسل برابر با 25 میلی وات بر متر مربع و کمترین عدد مربوط به اپراتور همراه اول در بیشترین فاصله عمودی به میزان 02/0 میلی وات بر متر مربع ثبت گردیده است. با توجه به آزمون میکس مدل ارتباط معنادار آماری بین ارتفاع سنجش و میانگین چگالی توان در هر دو نوع اپراتور مشاهده گردید. نتیجه‌گیری: هرچه ارتفاع سنجش از سطح زمین فاصله بیشتری گرفت و به عبارت دیگر به آنتن نزدیکتر شد و میانگین چگالی توان به طور معناداری در هر دو نوع اپراتور همراه اول و ایرانسل افزایش یافت ، افراد مستقر در ساختمان‌های بلند که در موازات ارتفاع نصب آنتن‌ها و یا در فاصله عمودی کمتری از آنها هستند، بیشتر در معرض تماس این امواج هستند.}, keywords_fa = {آنتن‌های BTS, چگالی توان, میدان الکترومغناطیسی, میکروویو, سنجش عمودی }, doi = {10.18869/acadpub.jehe.1.1.30}, url = {http://jehe.abzums.ac.ir/article-1-26-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-26-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Niazi, Sadegh and Mazlomi, Sajad and Shirzad, Mohammad Reza and Mokamelkande, Adel and Ahmadi, Farh}, title = {Survey the Outbreak of Giardiasis Among Food Supply and Distribution Staff of South Pars Economic Zone Petrochemicals}, abstract ={Background & Objectives: Giardiasis is one of the parasitic infections in the gastrointestinal tract which caused by flagellate protozoa that called giardia and it causes diarrhea. Giardia cysts defecate from infected people. These cysts can enter the body through contaminated hands, water, and food products. Diarrhea, weight loss, abdominal pains, growth failure, malabsorption of carbohydrates, fats and vitamins are the giardiasis symptoms. Methods: In this study, samples were taken from 203 people that were working in different food supply and distribution centers in the South Pars petrochemical. After sampling, samples were analyzed according to standard procedures. The results of examinations were studied after verification them by laboratory chief and their related physicians. Results: Out of the whole examined people in this study, kitchen (28%) and salad maker (14%) centers were the maximum and minimum population, respectively. 8.87% of the total populations were infected by giardia, which salad making center had the greatest share. As well as, the rate of infectious by giardia among the administrative and dishes washing centers was the lowest. Conclusion: Education level and personal hygiene such as hand washing with a detergent can be important in reducing infection due to giardia. So, the training of workers and also periodic testing of individuals can reduce these pollutants.}, Keywords = {giardiasis, food product, production and distribution, personal hygiene, of South Pars economic zone }, volume = {1}, Number = {1}, pages = {37-43}, publisher = {alborz university of medical sciences}, title_fa = {بررسی شیوع ژیاردیازیس در بین کارکنان مراکز تهیه و توزیع مواد غذایی پتروشیمی‌های منطقه اقتصادی پارس جنوبی}, abstract_fa ={زمینه و هدف: ژیاردیازیس از عفونت‌های انگلی دستگاه گوارش بوده که ناشی از  پروتوزوای تاژکداری به نام ژیاردیا لامبلیا  می‌باشد و باعث اسهال می‌شود. کیست ژیاردیا همراه مدفوع از افراد آلوده دفع می‌شود. این کیست ها می‌توانند از طریق آب، غذا و دست وارد بدن انسان شوند. علائم بیماری ژیاردیازیس بصورت اسهال، کاهش وزن، دردهای شکمی، نقص در رشد، سوء جذب قندها، چربی‌ها و ویتامین‌ها خود را نشان می‌دهد. روش بررسی: در این تحقیق، نمونه‌ها از 203 نفر که در اصناف مختلف مراکز تهیه و توزیع مواد غذایی پتروشیمی‌های پارس جنوبی مشغول به کار بودند  تهیه شد. پس از نمونه برداری بر اساس روش‌های استاندارد، نمونه‌ها مورد آنالیز قرار گرفتند. نتایج آزمایشات پس از تائید مسئول آزمایشگاه و پزشک مورد بحث و بررسی قرار گرفتند. یافته‌ها: از مجموع افراد مورد مطالعه در این تحقیق، صنف آشپز (28%) و واحدهای سالادسازی (14%) به ترتیب بیشترین و کمترین تعداد افراد اصناف را تشکیل می‌دادند. 87/8 % از کل جمعیت مورد مطالعه به ژیاردیا آلوده بودند که واحد سالادسازی بیشترین سهم را به خود اختصاص داده بود. همچنین میزان عفونت با ژیاردیا در واحدهای اداری و شستشوی ظروف کمترین بود. نتیجه گیری: سطح تحصیلات و رعایت بهداشت فردی مانند شستشوی دست‌ها با یک دترجنت می‌تواند نقش مهمی در کاهش آلودگی به انگل ژیاردیا داشته باشد. لذا آموزش شاغلین این اصناف و همچنین آزمایشات دوره‌ای افراد می‌تواند باعث کاهش این آلودگی ها شود.             }, keywords_fa = {ژیاردیازیس, محصولات غذایی, مراکز تهیه و توزیع, بهداشت فردی, منطقه اقتصادی پارس جنوبی}, doi = {10.18869/acadpub.jehe.1.1.37}, url = {http://jehe.abzums.ac.ir/article-1-27-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-27-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Foroghi, Maryam and Ebrahimi, Afshin and Esmaili, Hamze and Saeidi, Mahdi}, title = {Humic Acid Adsorption Onto Iron Oxide Magnetic Nano Particles in Aquious Solution}, abstract ={Background & Objectives: Humic Acid (HA) compounds affects water quality, such as color, taste and odor. The compounds not only react with disinfectants to produce disinfection by-products (DBPs) harmful to human health. Iron oxide magnetic nanoparticles (MNPs) have a high adsorption capacity to adsorb to organic matter. In this study HA removal by IOMNPs was surveyed in aqueous solutions. Methods:  The effects of pH value, agitation rate, adsorbent dose, contact time and the adsorbate concentration on the adsorption efficiency were studied as critical parameters. In addition, effect of ionic strength on the adsorption process and effluent turbidity was surveyed. The MNPs was characterized by X-ray diffraction. Results: Results revealed that at HA concentration of 10 mg/L, pH 4.5, adsorbent dose of 2.7 g/l, agitation rate of 250 rpm and contact time of 90 min at presence of 0.1 M NaCl as an ionic strength agent, the HA removal reached to about 98%. Also, the turbidity of treated samples was increased with increasing of HA loading. On the other hand, increases of ionic strength resulting in increase of removal efficiency and decrees of effluent turbidity. Conclusion: With increasing HA concentration, adsorption capacity of MNPs was increased and HA removal efficiency was decreased. Increasing of ionic strength leads to increase of removal efficiency and decrease of nano particles release. MNPs are easily attracted to the magnetic field application leads to easy separation from aquatic environment.}, Keywords = {Adsorption, Humic acid, Iron oxide magnetic nanoparticles}, volume = {1}, Number = {1}, pages = {44-55}, publisher = {alborz university of medical sciences}, title_fa = {تعیین کارایی حذف هیومیک اسید از محلول‌های آبی با استفاده از نانو ذرات مغناطیسی}, abstract_fa ={زمینه و هدف: ترکیبات هیومیک اسید (HA) باعث مشکلات بی‌شماری در صنعت آب و تصفیه زیستی خاک می‌شوند. این ترکیبات ایجاد طعم ناخوشایند و رنگ در آب نموده و جزء مهمترین پیش سازهای محصولات جانبی گندزدایی آب بشمار می‌روند. نانو ذرات مغناطیسی بدلیل اندازه کوچک و قدرت تفکیک آلاینده‌های محیط زیست-از جمله آلاینده‌های آب و فاضلاب- در تصفیه آلاینده‌های سمی و خطرناک و بهسازی محیط‌های آلوده کاربرد دارند. هدف از انجام مطالعه حاضر بررسی کارایی حذف HA با استفاده از MNP وتعیین شرایط بهینه در حذف می­باشد. روش بررسی: حذف هیومیک اسید از محلول‌های آبی بر روی نانو ذرات مغناطیسی  بعنوان تابعی از pH، غلظت HA، زمان تماس، دوز نانو ذرات مغناطیسی و سرعت اختلاط بصورت ناپیوسته مورد مطالعه قرار گرفت و بهینه شرایط حذف بدست آمد. همچنین اثرات قدرت یونش بر فرایند جذب و کدورت خروجی از نمونه‌ها بررسی شد. خصوصیات MNP با استفاده از پراش اشعه ایکس (XRD) و pH نقطه صفر بار سطحی (pHpzc) تعیین شد. یافته‌ها: راندمان حذف HA با دوز MNP رابطه مستقیم، و با غلظت HA و pH رابطه عکس دارد، همچنین افزایش زمان تماس تا 90 دقیقه و افزایش شدت اختلاط تا rpm 250، افزایش راندمان را سبب می­شدند. بهینه میزان حذف HA در 5/4pH=، دوز نانو ذرات مغناطیسی g/L 7/2، غلظت HAmg/L 10، شدت اختلاط rpm 250، زمان تماس 90 دقیقه و قدرت یونش برابر با mol/L1/0، به 8/98 درصد رسید. اگرچه با افزایش بارگذاری HA، کدورت خروجی از نمونه‌ها افزایش یافت اما از طرف دیگر افزایش قدرت یونش ضمن افزایش راندمان حذف، بطور چشمگیری کدورت خروجی را کاهش داد. نتیجه‌گیری: نانو ذرات مغناطیسی قادر به حذف درصد بالایی از HA می‌باشند. با افزایش قدرت یونش محلول، ضمن حصول راندمان حذف بیشتر، فرار نانو ذرات نیز کاهش می‌یابد. یکی از مزایای استفاده از MNP توانایی جداسازی آن‌ها از سوسپانسیون‌ها با استفاده از یک میدان مغناطیسی و احیای آن‌ها با استفاده از روش‌های مختلف و کاربرد مجدد آن‌ها است که همین امر می‌تواند هزینه تمام شده تصفیه خانه‌ها را کاهش دهد.}, keywords_fa = {هیومیک اسید, جذب سطحی, نانو ذرات مغناطیسی, محلول‌های آبی}, doi = {10.18869/acadpub.jehe.1.1.44}, url = {http://jehe.abzums.ac.ir/article-1-28-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-28-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Razavi, Marzieh and saeidi, Mohsen and Komasi, Mahdi}, title = {Assessment of Electrocoagulation Method for Simultaneous Removal of Phosphate, Nitrate and COD by Fe Electrodes from Laundry Wastewater}, abstract ={Background & Objectives: Discharging of wastewaters containing detergents either by manufacturers or through domestic and industrial usages has caused the incidence of serious environmental problems. Entering these materials in to the surface waters reduces the amount of dissolved oxygen in the water and causes unsightly environment and groundwater pollution that is always has been notified by environmental experts. Methods: This study focuses on the treatment of laundry wastewater containing phosphate, nitrate and COD using iron as sacrificial electrode by EC process. Various operating conditions such as pH (3, 4, 5, 6, 7, 9), distance between the electrode (3, 5, 10,15mm) and current density (3, 6,9,12 mA/cm2) were investigated. Results: Experimental results showed that pollutant removal efficiency varied by changing pH, distance between the electrodes and current density. According to the results, optimum operating conditions for the removal of phosphate, nitrate and COD, were current density of 12mA/cm2, pH of 7.0, distance between the electrodes equal to 10 mm with Fe electrodes. The removal efficiency of phosphate, nitrate and COD were showed 99.33%, 96.67% and 91.43%. Also Kinetic analysis indicates that the adsorption system obeys a second- order kinetic model. Conclusion: According to the results, the Fe electrodes have been achieved the high removal efficiency of phosphate, nitrate and COD by using electrocoagulation.}, Keywords = {Electro-coagulation, Phosphate, Nitrate, COD }, volume = {1}, Number = {1}, pages = {56-66}, publisher = {alborz university of medical sciences}, title_fa = {ارزیابی کاربرد روش انعقاد الکتریکی در حذف همزمان فسفات، نیترات و COD از پساب رختشوی‌خانه}, abstract_fa ={زمینه و هدف: تخلیه و ورود فاضلاب­های حاوی شوینده­ها چه از طریق کارخانجات سازنده و چه از طریق مصارف خانگی و صنعتی باعث بروز مسائل و مشکلات زیست محیطی عدیده ای گردیده است. ورود این مواد به آب­های سطحی، سبب کاهش میزان اکسیژن محلول در آب، بد منظره شدن محیط و آلودگی آب­های زیرزمینی می­شود که همواره مورد توجه کارشناسان محیط زیست بوده است. روش بررسی: در این پژوهش به بررسی حذف همزمان سه فاکتور فسفات، نیترات و COD با استفاده از روش انعقاد الکتریکی و الکترودهای آهنی پرداخته شد. راندمان حذف پارامترهای ذکر شده با استفاده از شش pH مختلف (3، 4، 5، 6، 7 و 9) ، همراه با تغییرات فاصله بین الکترودهای قرار گرفته در نمونه مورد مطالعه (3و5و10و15میلیمتر) و همچنین تغییرات چگالی جریان (3-12 میلی آمپر بر سانتیمتر مربع) انجام شد. همچنین سینتیک درجه 1 و2 واکنش بررسی گردیده و آنالیز XRF لجن بدست آمده از پساب ارائه گردید. یافته‌ها: نتایج بدست آمده نشان داد که pH ، فاصله بین الکترودها و همچنین شدت جریان الکتریکی سه پارامتر موثر در کارایی حذف فاکتورهای مذکور می‌باشد. بهترین کارایی حذف آلاینده ها در pH=7 ، فاصله بین الکترود برابر با ده میلی‌متر و شدت جریان الکتریکی دوازده میلی‌آمپر بر سانتی‌متر مربع به دست آمد. کارایی حذف فسفات، نیترات و COD در شرایط بهینه به ترتیب 33/99%، 67/96% و 43/91% به دست آمد. نتایج نشان داد که سینتیک واکنش فرآیند حذف فسفات از مدل سینتیکی درجه دوم پیروی می‌کند. نتیجه گیری: مطابق نتایج به دست آمده، فلز آهن در حذف فسفات، نیترات و COD با استفاده از روش انعقاد الکتریکی عمکرد بسیار خوبی داشته و به راندمان‌های حذف بالایی با استفاده از این روش دست یافته شده است.}, keywords_fa = {انعقاد الکتریکی, فسفات, نیترات, COD}, doi = {10.18869/acadpub.jehe.1.1.56}, url = {http://jehe.abzums.ac.ir/article-1-29-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-29-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} } @article{ author = {Alimohemadi, Mahmood and Dehghanifard, Emad and BodaghiMalidareh, Hajar}, title = {A Survey of Microbial Contamination of the Ice Blocks in the Ice-Making Factories and Sales Centers Ghaemshahr}, abstract ={Backgrounds and Objectives: Ice contamination comes from different ways. Considering the importance of hygiene of ice the purpose of this study was to investigate microbial contamination of the ice-making factories and sales centers in Ghaemshahr. Materials and Methods: In this Cross - sectional study, 6 & 20 samples were collected randomly from 2 ice-making factory and sales centers. Six water samples were taken from the factory. They were then transferred to lab. Every ice sample was tested before and after washing with water. Then Total Coli forms and Escherichia coli were determined. Results: The results showed that water sample is without pollution. The sample of the ice-making unit A isn´t safe. Unit B isn´t. E.Coli contamination but has 2 cases of coliform contamination. The ice sale place has (before & after Washing with water) respectively 95% -80%  E.Coli contamination and 100% total coliform. Conclusion: There isn´t any relationship between water quality and microbial contamination .Sanitary conditions Unit A is better than B. Personal hygiene, work tools and Building had a positive effect in contamination of ice. The results suggest that more attention of health system to control and prevent microbial contamination of ice is necessary.}, Keywords = {Microbial contamination, Ice blocks, Ghaemshahr}, volume = {1}, Number = {1}, pages = {67-74}, publisher = {alborz university of medical sciences}, title_fa = {بررسی آلودگی میکروبی یخ قالبی واحد‌های تولید و مراکز فروش یخ در شهر قائمشهر}, abstract_fa ={زمینه و هدف: آلودگی یخ از راه های مختلف بوجود می آید. با توجه به اهمیت بهداشت یخ، هدف از این مطالعه شناخت آلودگی میکروبی یخ قالبی واحد‌های تولید و مراکز فروش شهر قائمشهر می‌باشد. روش بررسی: مطالعه حاضر به روش مقطعی- توصیفی بوده که در شهرستان قائم شهر استان مازندران انجام گردید. نمونه‌های یخ از 2 واحد تولید، 10 مرکز فروش یخ، به ترتیب 6 و 20 نمونه یخ طی 2 ماه مرداد و شهریور، برداشته شده و 6 نمونه از آب تامین کننده یخ نیز تهیه وسریعاً به آزمایشگاه منتقل گردید و هر نمونه یخ، قبل و بعد از شستشو با آب، آزمایش و از نظر آلودگی کل کلیفرم و اشریشیاکلی مورد بررسی قرار گرفتند. یافته ها: نتایج نشان داد که نمونه‌های آب، سالم بوده است. نمونه‌های واحد A، دارای آلودگی بوده و واحدB، آلودگی اشریشیاکلی نداشته امّا دو مورد، آلودگی کلیفرمی جدا شد. آلودگی توتال کلیفرم نمونه‌های یخ مراکز فروش محرز و آلودگی اشریشیاکلی، قبل و بعد از شستشو با آب به ترتیب (95% و80%) بوده است. نتیجه گیری: آزمون های آماری نشان داد که رابطه‌ای بین کیفیت آب مصرفی و آلودگی میکروبی یخ دیده نشده و واحد B دارای وضعیت بهداشتی مطلوبتری نسبت به واحدA  بوده است. شرایط بهداشت فردی، ابزار کار، مکان تولید و فروش یخ در آلودگی یخ و تشدید آن دارای تاثیر مثبت می‌باشد. با توجه به نتایج، توجه بیشتر دست اندرکاران امور بهداشتی در نظارت، کنترل واحدها و مراکز فروش یخ ضروری است.}, keywords_fa = {: آلودگی میکروبی, یخ قالبی, قائمشهر}, doi = {10.18869/acadpub.jehe.1.1.67}, url = {http://jehe.abzums.ac.ir/article-1-30-en.html}, eprint = {http://jehe.abzums.ac.ir/article-1-30-en.pdf}, journal = {Journal of Environmental Health Enginering}, issn = {2383-3211}, eissn = {2588-4239}, year = {2013} }